M_AUDIO_LOUDNESS Structure Members

The following tables list the members exposed by M_AUDIO_LOUDNESS.

Public Fields
 NameDescription
Public FieldarrEBUMode_IIntermediate (from start) ‘EBU Mode’ metering, original and output audio.  
Public FieldarrEBUMode_MMoment (400 msec) ‘EBU Mode’ metering, original and output audio.  
Public FieldarrEBUMode_SShort (3000 msec) ‘EBU Mode’ metering, original and output audio.  
Public FieldarrPeaks_QPPMQPPM (Quasi Peak Programme Meter) peaks (10 msec integration) for one frame.  
Public FieldarrPeaks_TPLEBU TPL (True Peak Level) peaks for one frame.  
Public FieldarrRMSLoudless for the frame in dBFS (sin).  
Public FieldarrVUMeterANSI C 16.5 IEC 268-17 VU Meter level in dBFS (sin): -90 dB is silence, 0 dB is max audio (300 msec / 90% attack, 300 msec / 10% release).  
Public FieldarrVUPeaksVU Meter peaks in dBFS (sin): -90 dB is silence, 0 dB is max audio.  
Public FieldnTracksSplitBitTrack split bits.  
Public FieldnValidChannelsNumber of valid channels.  
Public FieldnValidTracksNumber of valid tracks.  
Top
See Also

Reference

M_AUDIO_LOUDNESS Structure